To review a supplier’s certificate of analysis, read it against your own specification for that material, one parameter at a time: what was tested, by which method, against which limit, and what the actual result was. A certificate that gives a verdict without a number, or a result without a limit, has not answered the question yet.
A certificate of analysis (CoA) is a supplier’s report of its own test results for one lot of the material it ships. A specification is your side of the exchange: the written criteria the material has to meet. The review below works on a raw-material certificate in cosmetics, supplements or food.
What to check on every certificate
- Confirm it is a certificate for your lot. The material, grade, supplier and lot number match what you received. A typical-properties sheet or a supplier’s own specification sheet describes the product in general, not the lot.
- Find every parameter in your specification. A parameter the certificate leaves out has not been reported. Silence is not a pass.
- Read the actual result. “Complies,” “passes” or “conforms” says a limit was met. It does not say what was found. Ask for the number.
- Read the method and the limit beside each result. For “none detected” or “ND,” find the detection limit and its units. A limit above the level your specification needs cannot support it. “None Detected” on a CoA explains why.
- Put units and basis side by side. Percent against parts per million (ppm), as-is against dry basis. Convert before you compare.
- Match the name to your record. A trade name or a chemical name is not an INCI name, the standardized ingredient name used on cosmetic labels. The CAS number, a registry number for the substance itself, is what ties the names together.
- Check the dates. The date of analysis, any retest or expiry date, and the date on every statement filed with the certificate, such as an allergen, origin or free-from declaration.
- Compare it with the last one. A new limit, a different method, a new manufacturing site or a parameter that has disappeared is a change, even when every line still passes.
- Write down the outcome. What you accepted, what you asked the supplier for, and why.
What US rules ask of a certificate
Two US manufacturing rules set conditions on believing a certificate. For dietary supplements, 21 CFR 111.75 lets a manufacturer rely on a supplier’s certificate only on conditions, one of which is that the certificate “includes a description of the test or examination method(s) used, limits of the test or examinations, and actual results of the tests or examinations.” For drugs, 21 CFR 211.84 accepts a supplier’s report of analysis in place of the manufacturer’s own testing “provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier’s analyses through appropriate validation of the supplier’s test results at appropriate intervals.” Both are quoted from the Electronic Code of Federal Regulations as current on November 6, 2026.
Cosmetics have no federal rule of that kind yet. The Modernization of Cosmetics Regulation Act of 2022 tells FDA to establish good manufacturing practice by regulation, and as of November 11, 2026, FDA has not published a proposed rule. The supplement rule is set out in Supplement raw-material CoAs, the cosmetics position in MoCRA supplier documentation, and the drug rule in Can a Supplier’s CoA Replace Your Own Testing?
Where the review gets harder
One certificate against one specification is the simple case. The file a team holds for a raw material is wider than that, and its pieces do not always agree:
- A certificate that says “none detected” and gives no detection limit, beside a specification that needs a number.
- A heavy-metals line that reports lead and nothing else, against a record that says “heavy metals: none.”
- An allergen or free-from statement issued before the supplier changed its process, still filed as current.
- A safety data sheet (SDS), the supplier’s hazard and handling document, that uses a trade name, a certificate that uses a chemical name, and a record that needs the INCI name.
- The same impurity in ppm on one document and in percent on another.
- A long, unstructured dossier in which one sentence changes what the record should say.
- A supplier’s email that corrects the certificate and was never filed with it.
Done by hand it is careful, repetitive reading: open the file, find the statement, retype the value, compare it against the previous revision and against every other document in the folder.
Where Elara fits
Smart-Suited Tech’s document agent, Elara, reads supplier certificates of analysis, safety data sheets, regulatory statements and full dossiers against your specifications, reconciles anything that conflicts with the live record, and shows you, with evidence, exactly what changed. Conflicts between documents are resolved by rule, with the reason on the record, and compliance-critical changes are surfaced for a person to decide. Accepting or rejecting a lot, qualifying a supplier and any testing stay with your quality unit.
The one completed pilot to date, with a cosmetics company, is written up in the RCMA case study.
Sources
- 01 21 CFR 111.75: What must you do to determine whether specifications are met? — Electronic Code of Federal Regulations, current as of November 6, 2026, read November 11, 2026
- 02 21 CFR 211.84: Testing and approval or rejection of components, drug product containers, and closures — Electronic Code of Federal Regulations, current as of November 6, 2026, read November 11, 2026
- 03 21 U.S.C. 364b: Good manufacturing practice (section 606 of the Federal Food, Drug, and Cosmetic Act) — United States Code, added by Pub. L. 117-328, December 29, 2022
- 04 Good Manufacturing Practice for Cosmetic Product Facilities, RIN 0910-AJ00 — Unified Agenda, reginfo.gov, read November 11, 2026
- 05 Federal Register search, RIN 0910-AJ00 — Office of the Federal Register, no document found November 11, 2026